Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Sci Rep ; 12(1): 16070, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36168032

RESUMO

In prostate MRI, single-shot EPI (ssEPI) DWI still suffers from distortion and blurring. Multi-shot EPI (msEPI) overcomes the drawbacks of ssEPI DWI. The aim of this article was to compare the image quality and diagnostic performance for clinically significant prostate cancer (csPC) between ssEPI DWI and msEPI DWI. This retrospective study included 134 patients with suspected PC who underwent 3.0 T MRI and subsequent MRI-guided biopsy. Three radiologists independently assessed anatomical distortion, prostate edge clarity, and lesion conspicuity score for pathologically confirmed csPC. Lesion apparent diffusion coefficient (ADC) and benign ADC were also calculated. In 17 PC patients who underwent prostatectomy, three radiologists independently assessed eight prostate regions by DWI score in PI-RADS v 2.1. Anatomical distortion and prostate edge clarity were significantly higher in msEPI DWI than in ssEPI DWI in the three readers. Lesion conspicuity score was significantly higher in msEPI DWI than in ssEPI DWI in reader 1 and reader 3. Regarding discrimination ability between PC with GS ≤ 3 + 4 and PC with GS ≥ 4 + 3 using lesion ADC, AUC was comparable between ssEPI DWI and msEPI DWI. For diagnostic performance of csPC using DWI score, AUC was comparable between msEPI DWI and ssEPI DWI in all readers. Compared with ssEPI DWI, msEPI DWI had improved image quality and similar or higher diagnostic performance.


Assuntos
Próstata , Neoplasias da Próstata , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Br J Radiol ; 95(1138): 20211294, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35830235

RESUMO

We present the application of three-dimensional susceptibility-weighted imaging technique for evaluation of pathologies of the spine and spinal cord. This work focuses on the advantage of this imaging technique as an adjunct to the conventional imaging to evaluate various disorders of the spine and spinal cord like trauma, degenerative diseases, vascular malformations, and tumours, where susceptibility-weighted imaging may offer valuable harmonising evidence that may be helpful in the diagnosis and management of the patients with these pathologies.


Assuntos
Doenças da Medula Espinal , Medula Espinal , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Medula Espinal/diagnóstico por imagem , Medula Espinal/patologia , Doenças da Medula Espinal/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem
3.
Diagn Interv Radiol ; 28(2): 131-137, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35548897

RESUMO

PURPOSE We aimed to evaluate the relative contribution of susceptibility weighted imaging (SWI) in the detection of common bile-duct (CBD) stones in comparison to the conventional MRI protocol containing magnetic resonance cholangiopancreatography (MRCP), balanced turbo field echo (BTFE), and T2-weighted spin-echo imaging techniques. METHODS MRI data containing MRCP, BTFE, T2-weighted imaging, and abdominal SWI were independently evaluated by 2 sets of experienced radiologists in 44 patients with confirmed CBD stones. Endoscopic retrograde cholangiopancreatography, and endoscopic ultrasound where available, was used as the reference gold standard. Evaluation was performed for the visualization of CBD stones in each of the MRI techniques. Relative contribution of SWI was classified into one of four categories for each case: (1) no contribution to CBD stone visualization; (2) same as conventional techniques; (3) improved diagnostic confidence; and (4) critical for diagnosis. Stone size was also assessed. RESULTS Inter-rater agreement coefficient for CBD stone visualization was found to be "good" in MRCP (0.77), "very good" in SWI (0.94) and BTFE (0.84), and moderate in T2-weighted imaging (0.54). CBD stones were visualized with SWI in 86.4% and 82%, with MRCP in 70.5% and 70.5% cases, with BTFE in 73% and 61.4% cases, with T2-weighted imaging in 45.5% and 52.3% cases by reviewers 1 and 2, respectively. SWI did not contribute to CBD stone visualization in 2.3% (1/44); was the same as conventional techniques in 31.8% (14/44) cases; improved diagnostic confidence in 34.1%; and was critical for diagnosis in 20.5% cases. CONCLUSION SWI has the potential to serve as a strong adjunct to conventional MRI protocols used for CBD stone evaluation with very small scan-time penalty.


Assuntos
Bile , Cálculos Biliares , Colangiopancreatografia Retrógrada Endoscópica , Colangiopancreatografia por Ressonância Magnética/métodos , Cálculos Biliares/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos
4.
Fetal Diagn Ther ; 47(2): 145-155, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31434069

RESUMO

OBJECTIVE: To evaluate a dual-imaging modality approach to obtain a combined estimation of venous blood oxygenation (SνO2) using susceptibility-weighted magnetic resonance imaging (SWI-MRI), and blood perfusion using power Dopp-ler ultrasound (PDU) and fractional moving blood volume (FMBV) in the brain of normal growth and growth-restricted fetuses. METHODS: Normal growth (n = 33) and growth-restricted fetuses (n = 10) from singleton pregnancies between 20 and 40 weeks of gestation were evaluated. MRI was performed and SνO2 was calculated using SWI-MRI data obtained in the straight section of the superior sagittal sinus. Blood perfusion was estimated using PDU and FMBV from the frontal lobe in a mid-sagittal plane of the fetal brain. The association between fetal brain SνO2 and FMBV, and the distribution of SνO2 and FMBV values across gestation were calculated for both groups. RESULTS: In growth-restricted fetuses, the brain SνO2 values were similar, and the FMBV values were higher across gestation as compared to normal growth fetuses. There was a significantly positive association between SνO2 and FMBV values (slope = 0.38 ± 0.12; r = 0.7; p = 0.02) in growth-restricted fetuses. In normal growth fetuses, SνO2 showed a mild decreasing trend (slope = -0.7 ± 0.4; p = 0.1), whereas FMBV showed a mild increasing trend (slope = 0.2 ± 0.2; p = 0.2) with advancing gestation, and a mild but significant negative association (slope = -0.78 ± 0.3; r = -0.4; p = 0.04) between these two estimates. CONCLUSION: Combined MRI (SWI) and ultrasound (FMBV) techniques showed a significant association between cerebral blood oxygenation and blood perfusion in normal growth and growth-restricted fetuses. This dual-imaging approach could contribute to the early detection of fetal "brain sparing" and brain oxygen saturation changes in high-risk pregnancies.


Assuntos
Circulação Cerebrovascular , Imagem de Difusão por Ressonância Magnética , Retardo do Crescimento Fetal/diagnóstico por imagem , Hemodinâmica , Artéria Cerebral Média/diagnóstico por imagem , Oxigênio/sangue , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Adolescente , Adulto , Biomarcadores/sangue , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Estudos Transversais , Feminino , Retardo do Crescimento Fetal/fisiopatologia , Idade Gestacional , Humanos , Artéria Cerebral Média/fisiopatologia , Valor Preditivo dos Testes , Gravidez , Estados Unidos , Adulto Jovem
5.
J Comput Assist Tomogr ; 43(5): 747-754, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31356527

RESUMO

OBJECTIVE: To evaluate the visualization of gallbladder stones on susceptibility-weighted imaging (SWI). MATERIALS AND METHODS: Imaging data from 47 patients who underwent clinically indicated cholecystectomy was reviewed. Breath-hold SWI was added to the magnetic resonance imaging protocol and magnitude and phase data was reviewed for gall-stones visualization. Phase signature, that is, diamagnetic, paramagnetic, or mixed, was also noted in the stones. Magnetic susceptibility value of surgically extracted gallstones were imaged ex vivo (n = 37). RESULTS: In 45 of 47 cases, gallstones were surgically confirmed. In 43 cases, gallstones were visualized in the SWI. In 1 case, although routine imaging failed, stones were visualized on SWI. In 29 diamagnetic, 7 paramagnetic and 9 cases mixed phase were seen. In an ex vivo study, magnetic susceptibility of stones was found ranging between -0.102 and -0.916 ppm for diamagnetic and 0.203 and 486 ppm for paramagnetic stones. CONCLUSIONS: Gallbladder stones can be visualized with SWI and may be added to the routine magnetic resonance imaging protocol for its evaluation.


Assuntos
Cálculos Biliares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Colecistectomia , Feminino , Cálculos Biliares/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos
6.
Eur Radiol ; 29(4): 2017-2026, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30276673

RESUMO

OBJECTIVES: To present the feasibility of performing quantitative susceptibility mapping (QSM) in the human fetus to evaluate the oxygenation (SvO2) of cerebral venous blood in vivo. METHODS: Susceptibility weighted imaging (SWI) data were acquired from healthy pregnant subjects (n = 21, median = 31.3 weeks, interquartile range = 8.8 weeks). The susceptibility maps were generated from the SWI-phase images using a modified QSM processing pipeline, optimised for fetal applications. The processing pipeline is as follows: (1) mild high-pass filtering followed by quadratic fitting of the phase images to eliminate background phase variations; (2) manual creation of a fetal brain mask that includes the superior sagittal sinus (SSS); (3) inverse filtering of the resultant masked phase images using a truncated k-space approach with geometric constraint. Further, the magnetic susceptibility, ∆χv and corresponding putative SvO2 of the SSS were quantified from the generated susceptibility maps. Systematic error in the measured SvO2 due to the modified pipeline was also studied through simulations. RESULTS: Simulations showed that the systematic error in SvO2 when using a mask that includes a minimum of 5 voxels around the SSS and five slices remains < 3% for different orientations of the vessel relative to the main magnetic field. The average ∆χv in the SSS quantified across all gestations was 0.42 ± 0.03 ppm. Based on ∆χv, the average putative SvO2 in the SSS across all fetuses was 67% ± 7%, which is in good agreement with published studies. CONCLUSIONS: This in vivo study demonstrates the feasibility of using QSM in the human fetal brain to estimate ∆χv and SvO2. KEY POINTS: • A modified quantitative susceptibility mapping (QSM) processing pipeline is tested and presented for the human fetus. • QSM is feasible in the human fetus for measuring magnetic susceptibility and oxygenation of venous blood in vivo. • Blood magnetic susceptibility values from MR susceptometry and QSM agree with each other in the human fetus.


Assuntos
Mapeamento Encefálico/métodos , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Seio Sagital Superior/diagnóstico por imagem , Adulto , Veias Cerebrais , Feminino , Feto/metabolismo , Voluntários Saudáveis , Humanos , Masculino , Gravidez , Seio Sagital Superior/metabolismo
7.
Eur Radiol ; 28(5): 1884-1890, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29247352

RESUMO

OBJECTIVE: To evaluate the magnetic susceptibility, ∆χ v , as a surrogate marker of venous blood oxygen saturation, S v O 2, in second- and third-trimester normal human foetuses. METHODS: Thirty-six pregnant women, having a mean gestational age (GA) of 31 2/7 weeks, underwent magnetic resonance imaging (MRI). Susceptibility-weighted imaging (SWI) data from the foetal brain were acquired. ∆χ v of the superior sagittal sinus (SSS) was quantified using MR susceptometry from the intra-vascular phase measurements. Assuming the magnetic property of foetal blood, ∆χ do , is the same as that of adult blood, S v O 2 was derived from the measured Δχ v . The variation of ∆χ v and S v O 2, as a function of GA, was statistically evaluated. RESULTS: The mean ∆χ v in the SSS in the second-trimester (n = 8) and third-trimester foetuses (n = 28) was found to be 0.34± 0.06 ppm and 0.49 ±0.05 ppm, respectively. Correspondingly, the derived S v O 2 values were 69.4% ±3.27% and 62.6% ±3.25%. Although not statistically significant, an increasing trend (p = 0.08) in Δχ v and a decreasing trend (p = 0.22) in S v O 2 with respect to advancing gestation was observed. CONCLUSION: We report cerebral venous blood magnetic susceptibility and putative oxygen saturation in healthy human foetuses. Cerebral oxygen saturation in healthy human foetuses, despite a slight decreasing trend, does not change significantly with advancing gestation. KEY POINTS: • Cerebral venous magnetic susceptibility and oxygenation in human foetuses can be quantified. • Cerebral venous oxygenation was not different between second- and third-trimester foetuses. • Foetal cerebral venous oxygenation does not change significantly with advancing gestation.


Assuntos
Circulação Cerebrovascular , Imageamento por Ressonância Magnética/métodos , Consumo de Oxigênio/fisiologia , Oxigênio/sangue , Adulto , Encéfalo/irrigação sanguínea , Encéfalo/embriologia , Veias Cerebrais/diagnóstico por imagem , Feminino , Idade Gestacional , Humanos , Oximetria/métodos , Gravidez , Diagnóstico Pré-Natal/métodos , Reprodutibilidade dos Testes , Adulto Jovem
8.
J Magn Reson Imaging ; 48(1): 283-289, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29274251

RESUMO

BACKGROUND: Volumetric assessment of afferent blood flow rate provides a measure of global organ perfusion. Phase-contrast magnetic resonance imaging (PCMRI) is a reliable tool for volumetric flow quantification, but given the challenges with motion and lack of physiologic gating signal, such studies, in vivo on the human placenta, are scant. PURPOSE: To evaluate and apply a nongated (ng) PCMRI technique for quantifying blood flow rates in utero in umbilical vessels. STUDY TYPE: Prospective study design. STUDY POPULATION: Twenty-four pregnant women with median gestational age (GA) 30 4/7 weeks and interquartile range (IQR) 8 1/7 weeks. FIELD STRENGTH/SEQUENCE: All scans were performed on a 3.0T Siemens Verio system using the ng-PCMRI technique. ASSESSMENT: The GA-dependent increase in umbilical vein (UV) and arterial (UA) flow was compared to previously published values. Systematic error to be expected from ng-PCMRI, in the context of pulsatile UA flow and partial voluming, was studied through Monte-Carlo simulations, as a function of resolution and number of averages. STATISTICAL TESTS: Correlation between the UA and UV was evaluated using a generalized linear model. RESULTS: Simulations showed that ng-PCMRI measurement variance reduced by increasing the number of averages. For vessels on the order of 2 voxels in radius, partial voluming led to 10% underestimation in the flow. In fetuses, the average flow rates in UAs and UV were measured to be 203 ± 80 ml/min and 232 ± 92 ml/min and the normalized average flow rates were 140 ± 59 ml/min/kg and 155 ± 57 ml/min/kg, respectively. Excellent correlation was found between the total arterial flow vs. corresponding venous flow, with a slope of 1.08 (P = 0.036). DATA CONCLUSION: Ng-PCMRI can provide accurate volumetric flow measurements in utero in the human umbilical vessels. Care needs to be taken to ensure sufficiently high-resolution data are acquired to minimize partial voluming-related errors. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2017.


Assuntos
Imageamento por Ressonância Magnética , Placenta/diagnóstico por imagem , Artérias Umbilicais/diagnóstico por imagem , Veias Umbilicais/diagnóstico por imagem , Adolescente , Adulto , Biomarcadores , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Feminino , Humanos , Modelos Teóricos , Movimento (Física) , Distribuição Normal , Gravidez , Estudos Prospectivos , Fluxo Pulsátil , Reprodutibilidade dos Testes , Adulto Jovem
9.
Eur Radiol ; 26(12): 4570-4576, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27189488

RESUMO

Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. KEY POINTS: • 3D-visualization of fetal vasculature is feasible using non-contrast MRA at 3.0 T. • Visualization of placental vasculature is also possible with this method. • Fetal MRA can serve as a vascular localizer for quantitative MRI studies. • This method can be extended to 1.5 T.


Assuntos
Vasos Sanguíneos/embriologia , Feto/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Meios de Contraste , Estudos de Viabilidade , Feminino , Feto/irrigação sanguínea , Humanos , Placenta/irrigação sanguínea , Placenta/diagnóstico por imagem , Gravidez , Doenças Vasculares/diagnóstico por imagem
10.
Placenta ; 43: 90-7, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26947613

RESUMO

INTRODUCTION: To evaluate changes in placental perfusion with advancing gestation in normal murine pregnancy using dynamic contrast enhanced magnetic resonance imaging (DCE-MRI). METHODS: Seven timed-pregnant CD-1 mice underwent DCE-MRI scanning longitudinally on gestational days (GD) 13, 15 and 17. Placentas were segmented into high (HPZ) and low perfusion zones (LPZ) using tissue similarity mapping. Blood perfusion of the respective regions and the whole placenta was quantified using the steepest slope method. The diameter of the maternal central canal (CC) was also measured. RESULTS: An increase in perfusion was observed between GD13 and GD17 in the overall placenta (p = 0.04) and in the HPZ (p = 0.02). Although perfusion in the LPZ showed a slight increasing trend, it was not significant (p = 0.07). Perfusion, in units of ml/min/100 ml, in the overall placenta and the HPZ was respectively 61.2 ± 31.2 and 106.2 ± 56.3 at GD13 (n = 19 placentas); 90.3 ± 43.7 and 139 ± 55.4 at GD15 (n = 20); and 104.9 ± 76.1 and 172.2 ± 85.6 at GD17 (n = 14). The size of the CC increased with advancing gestation (p < 0.05). DISCUSSION: Using longitudinal DCE-MRI, the gestational age-dependent perfusion change in the normal murine placenta and in its regional compartments was quantified. In mid and late gestations, placental constituent regions differ significantly in their perfusion rates. The CC diameter also showed increase with advancing gestation, which may be playing an important role toward the gestational age-dependent increase in placental perfusion.


Assuntos
Imageamento por Ressonância Magnética , Placenta/diagnóstico por imagem , Circulação Placentária/fisiologia , Animais , Feminino , Camundongos , Placenta/irrigação sanguínea , Gravidez
11.
Gynecol Obstet Invest ; 81(3): 193-201, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26336923

RESUMO

OBJECTIVE: To quantify gestation-dependent longitudinal changes in the magnetic resonance transverse relaxation time (T2) parameter of the major constituent regions of the mouse placenta and to evaluate their relative contributions to changes in overall placental T2. METHODS: Timed-pregnant CD-1 mice underwent magnetic resonance imaging at 7.0 T field strength, on gestational day 13 (GD13), GD15 and GD17. T2 of the placenta and its constituent high and low blood perfusion regions were quantified. A linear mixed-effects model was used to fit the T2 across gestation, and the significance of coefficients was tested. RESULTS: A decrease in the T2 values of the placenta and its constituent regions was observed across gestation. The temporal change in T2 was estimated to be -1.85 ms/GD (p < 0.0001) for the placenta, -1.00 ms/GD (p < 0.001) for the high-perfusion zones (HPZs) and -1.66 ms/GD (p < 0.0001) for the low-perfusion zones (LPZs). CONCLUSION: T2 of the constituent zones of the murine placenta decreases with advancing gestation. While the T2 of the LPZ is smaller than that of the HPZ, there is no difference in their decrease rate relative to that of the whole placenta (p = 0.24). The results suggest an increased role of constituent volume fractions in affecting overall gestation-dependent placental T2 decrease in mice.


Assuntos
Imageamento por Ressonância Magnética/veterinária , Placenta/diagnóstico por imagem , Placenta/fisiologia , Animais , Feminino , Idade Gestacional , Camundongos , Placenta/irrigação sanguínea , Gravidez
12.
Magn Reson Imaging ; 33(10): 1191-1204, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26248271

RESUMO

Recently a method called CISSCO (Complex Image Summation around a Spherical or a Cylindrical Object) was introduced for accurately quantifying the susceptibility and the radius of any narrow cylindrical object at any orientation using a typical two-echo gradient echo sequence. This work further optimizes the method for quantifying oxygen saturation in small cerebral veins in the human brain. The revised method is first validated through numerical simulations and then applied to data from phantom and human brain. The effect of phase high pass filtering on the quantified parameters is studied and procedures for mitigating its adverse effects are suggested. Uncertainty of each measurement is estimated from the error propagation method. It is shown that the revised method allows for accurate quantification of both the vessel size and its oxygen saturation even in the case of a low SNR (signal to noise ratio) in the vein. The results are self consistent across different veins within a given subject with a variation of less than 6%. Finally, imaging parameters and some procedures are suggested for accurate susceptibility and radius quantifications of small human veins.


Assuntos
Veias Cerebrais/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
13.
Magn Reson Imaging ; 33(4): 420-36, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25633922

RESUMO

A new method is developed to measure the magnetic susceptibilities and radii of small cylinder-like objects at arbitrary orientations accurately. This method for most biological substances only requires a standard gradient echo sequence with one or two echo times, depending on the orientation of an object relative to the main magnetic field. For objects oriented at the magic angle, however, this method is not applicable. As a byproduct of this method, the cross-sectional area as well as signals inside and outside the object can be determined. The uncertainty of each measurement is estimated from the error propagation method. Partial volume, dephasing, and phase aliasing effects are naturally included in the equations of this method. A number of simulations, phantom, and pilot in-vivo human studies are carried out to validate the theory. When the maximal phase value at the boundary of a given cylindrical object is larger than 3 radians, and the phase inside the object is more than 1 radian, the susceptibility can be accurately quantified within 15%. The radius of the object can be determined to subpixel accuracy. This is the case when the signal-to-noise ratio inside the object is about 6:1 or higher and the radius of the object is about one pixel or larger. These conditions are realistic when considering medullary and pial veins for example.


Assuntos
Vasos Sanguíneos/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Adulto , Algoritmos , Animais , Simulação por Computador , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Perinat Med ; 43(2): 209-20, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25324440

RESUMO

OBJECTIVES: Our two objectives were to evaluate the feasibility of fetal brain magnetic resonance imaging (MRI) using a fast spin echo sequence at 3.0T field strength with low radio frequency (rf) energy deposition (as measured by specific absorption rate: SAR) and to compare image quality, tissue contrast and conspicuity between 1.5T and 3.0T MRI. METHODS: T2 weighted images of the fetal brain at 1.5T were compared to similar data obtained in the same fetus using a modified sequence at 3.0T. Quantitative whole-body SAR and normalized image signal to noise ratio (SNR), a nominal scoring scheme based evaluation of diagnostic image quality, and tissue contrast and conspicuity for specific anatomical structures in the brain were compared between 1.5T and 3.0T. RESULTS: Twelve pregnant women underwent both 1.5T and 3.0T MRI examinations. The image SNR was significantly higher (P=0.03) and whole-body SAR was significantly lower (P<0.0001) for images obtained at 3.0T compared to 1.5T. All cases at both field strengths were scored as having diagnostic image quality. Images from 3.0T MRI (compared to 1.5T) were equal (57%; 21/37) or superior (35%; 13/37) for tissue contrast and equal (61%; 20/33) or superior (33%, 11/33) for conspicuity. CONCLUSIONS: It is possible to obtain fetal brain images with higher resolution and better SNR at 3.0T with simultaneous reduction in SAR compared to 1.5T. Images of the fetal brain obtained at 3.0T demonstrated superior tissue contrast and conspicuity compared to 1.5T.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Diagnóstico Pré-Natal/métodos , Adulto , Encéfalo , Feminino , Feto , Humanos , Gravidez , Estudos Prospectivos , Adulto Jovem
15.
Magn Reson Med ; 73(6): 2185-94, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25046134

RESUMO

PURPOSE: To demonstrate the mapping of structures with high susceptibility values, such as the sinuses, bones and teeth, using short echo times. METHODS: Four in vivo datasets were collected with a gradient-echo sequence (TE1 = 2.5 ms, TE2 = 5 ms and TE3 = 7.5 ms). Complex division was performed to remove the phase offset term and generate the phase at TE = 2.5 ms. Susceptibility maps were generated from unwrapped phase images, using a geometry-constrained iterative algorithm, by preserving phase information in the extracerebral tissues. The susceptibility results were improved by updating the missing phase information inside structures with no signal using the predicted phase at each iteration step. Simulated phase images of a three-dimensional brain model and tooth phantom were used to validate the proposed method. RESULTS: Improved susceptibility maps were obtained once the phase information in the extracerebral tissue region was incorporated, for both the model and in vivo data. For in vivo data, the average susceptibilities of air (sphenoid sinus), bone and calcium (teeth) were found to be (in ppm): Δχ(sinus-tissue) = +9.2 ± 1.3, Δχ(bone-tissue) = -2.1 ± 0.6 and Δχ(teeth-tissue) = -3.3 ± 1.2, respectively. CONCLUSION: High susceptibility structures with little or no signal can be imaged using quantitative susceptibility mapping and can be used to improve background field removal.


Assuntos
Ar , Cálcio/análise , Cabeça/anatomia & histologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Mapeamento Encefálico/métodos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Crânio/anatomia & histologia
16.
J Magn Reson Imaging ; 40(4): 949-57, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24989457

RESUMO

PURPOSE: To evaluate the feasibility of performing fetal brain magnetic resonance venography using susceptibility weighted imaging (SWI). MATERIALS AND METHODS: After obtaining informed consent, pregnant women in the second and third trimester were imaged using a modified SWI sequence. Fetal SWI acquisition was repeated when fetal or maternal motion was encountered. The median and maximum number of times an SWI sequence was repeated was four and six respectively. All SWI image data were systematically evaluated by a pediatric neuroradiologist for image quality using an ordinal scoring scheme: 1. diagnostic; 2. diagnostic with artifacts; and 3. nondiagnostic. The best score in an individual fetus was used for further statistical analysis. Visibility of venous vasculature was also scored using a dichotomous variable. A subset of SWI data was re-evaluated by the first and independently by a second pediatric neuroradiologist. Kappa coefficients were computed to assess intra-rater and inter-rater reliability. RESULTS: SWI image data from a total of 22 fetuses were analyzed. Median gestational age and interquartile range of the fetuses imaged were 32 (29.9-34.9) weeks. In 68.2% of the cases (n = 15), there was no artifact; 22.7% (n = 5) had minor artifacts and 9.1% (n = 2) of the data was of nondiagnostic quality. Cerebral venous vasculature was visible in 86.4% (n = 19) of the cases. Substantial agreement (Kappa = 0.73; 95% confidence interval 0.44-1.00)) was observed for intra-rater reliability and moderate agreement (Kappa = 0.48; 95% confidence interval 0.19-0.77) was observed for inter-rater reliability. CONCLUSION: It is feasible to perform fetal brain venography in humans using SWI.


Assuntos
Veias Cerebrais/anatomia & histologia , Veias Cerebrais/embriologia , Angiografia por Ressonância Magnética/métodos , Flebografia/métodos , Diagnóstico Pré-Natal/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
J Magn Reson Imaging ; 40(3): 698-708, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24923249

RESUMO

PURPOSE: To remove the geometry dependence of phase-based susceptibility weighting masks in susceptibility-weighted imaging (SWI) and to improve the visualization of the veins and microbleeds. MATERIALS AND METHODS: True SWI (tSWI) was generated using susceptibility-based masks. Simulations were used to evaluate the influence of the characteristic parameters defining the mask. In vivo data from three healthy adult human volunteers were used to compare the contrast-to-noise-ratios (CNRs) of the right septal vein and the left internal cerebral vein as measured from both tSWI and SWI data. A traumatic brain injury (TBI) patient dataset was used to illustrate qualitatively the proper visualization of microbleeds using tSWI. RESULTS: Compared with conventional SWI, tSWI improved the CNR of the two selected veins by a factor of greater than three for datasets with isotropic resolution and greater than 30% for datasets with anisotropic resolution. Veins with different orientations can be properly enhanced in tSWI. Furthermore, the blooming artifact due to the strong dipolar phase of microbleeds in conventional SWI was reduced in tSWI for the TBI case. CONCLUSION: The use of tSWI overcomes the geometric limitations of using phase and provides better visualization of the venous system, especially for data collected with isotropic resolution.


Assuntos
Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Veias/anatomia & histologia , Algoritmos , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
18.
J Magn Reson Imaging ; 39(4): 998-1006, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24783243

RESUMO

PURPOSE: To evaluate fetal cerebral venous blood oxygenation, Yv, using principles of MR susceptometry. MATERIALS AND METHODS: A cohort of 19 pregnant subjects, with a mean gestational age of 31.6 ± 4.7 weeks were imaged using a modified susceptibility-weighted imaging (SWI) sequence. Data quality was first assessed for feasibility of oxygen saturation measurement, and data from five subjects (mean ± std gestational age of 33.7 ± 3.6 weeks) were then chosen for further quantitative analysis. SWI phase in the superior sagittal sinus was used to evaluate oxygen saturation using the principles of MR susceptometry. Systematic error in the measured Y(v) values was studied through simulations. RESULTS: Simulations showed that the systematic error in Yv depended upon the assumed angle of the vessel, θ, relative to the main magnetic field and the error in that vessel angle δθ. For the typical vessel angle of θ = 30° encountered in the fetal data analyzed, a δθ as large as ±20° led to an absolute error, δYv, of less than 11%. The measured mean oxygen saturation across the five fetuses was 66% ± 9.4%. This average cerebral venous blood oxygenation value is in close agreement with values in the published literature. CONCLUSION: We have reported the first in vivo measurement of human fetal cerebral venous oxygen saturation using MRI.


Assuntos
Encéfalo/fisiopatologia , Veias Cerebrais/fisiopatologia , Circulação Cerebrovascular , Imagem de Difusão por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/métodos , Consumo de Oxigênio , Diagnóstico Pré-Natal/métodos , Adolescente , Adulto , Encéfalo/embriologia , Encéfalo/patologia , Veias Cerebrais/embriologia , Veias Cerebrais/patologia , Feminino , Humanos , Masculino , Oxigênio/sangue , Gravidez , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
19.
Gynecol Obstet Invest ; 78(1): 33-40, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24861575

RESUMO

OBJECTIVE: To evaluate gestational age-dependent changes in the T2 relaxation time in normal murine placentas in vivo. The role of susceptibility-weighted imaging (SWI) in visualization of the murine fetal anatomy was also elucidated. METHODS: Timed-pregnant CD-1 mice at gestational day (GD) 12 and GD17 underwent magnetic resonance imaging. Multi-echo spin echo and SWI data were acquired. The placental T2 values on GD12 and GD17 were quantified. To account for the influence of systemic maternal physiological factors on placental perfusion, maternal muscle was used as a reference for T2 normalization. A linear mixed-effects model was used to fit the normalized T2 values, and the significance of the coefficients was tested. Fetal SWI images were processed and reviewed for venous vasculature and skeletal structures. RESULTS: The average placental T2 value decreased significantly on GD17 (40.17 ± 4.10 ms) compared to the value on GD12 (55.78 ± 8.13 ms). The difference in normalized T2 values also remained significant (p = 0.001). Using SWI, major fetal venous structures like the cardinal vein, the subcardinal vein, and the portal vein were visualized on GD12. In addition, fetal skeletal structures could also be discerned on GD17. CONCLUSION: The T2 value of a normal murine placenta decreases with advancing gestation. SWI provided clear visualization of the fetal venous vasculature and bony structures. © 2014 S. Karger AG, Basel.


Assuntos
Feto/anatomia & histologia , Feto/irrigação sanguínea , Idade Gestacional , Imageamento por Ressonância Magnética , Animais , Feminino , Camundongos , Placenta/anatomia & histologia , Placenta/irrigação sanguínea , Gravidez , Veias/embriologia
20.
Magn Reson Med ; 70(1): 117-26, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22886762

RESUMO

Phase images reflect local field variations including susceptibility contributions and play a key role in a number of imaging applications. However, due to the limited dynamic range of phase values, phase wrapping invariably occurs at long echo times. High pass filtering and region-growing approaches have been common themes in the effort of removing phase wraps. In this article, a novel voxel-by-voxel phase unwrapping scheme taking advantage of short interecho spacing of multiecho gradient echo imaging is proposed. By removing spurious sources of phase variations and exploiting the special features of the flow-induced phase component, phase increments during adjacent echoes can be unveiled that exhibit no phase aliasing. This unaliased phase information is then used to unwrap all the phase images at all of the echoes. Data of 15 volunteers scanned at 3 and 1.5T were processed with the proposed algorithm and two other algorithms in the literature (PhUN and branch cut). It is shown that the proposed approach is fast and effective in unwrapping all the phase values even for voxels in the eyes and the skull, which the other algorithms failed to unwrap. Thus, in multiecho gradient echo imaging, the proposed algorithm has major potential in various applications involving phase processing.


Assuntos
Algoritmos , Artefatos , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Voluntários Saudáveis , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...